IR spectra using a KBr disc or a diamond ATR. Which is better?

2/9/2014

0 Comments

 
The old fashioned way to run IR spectra is by preparing a KBr disc. Sometime in the last decade, the diamond attenuated total reflectance (ATR) was introduced. Some people consider this input method to give the same result. However, the KBr disc method gives greater resolution than the ATR. You'll also find that the ATR method gives a lot of interference below 600 wavenumbers, which results in it only being practical to measure down to 650 cm-1, whereas with the KBr disc method one can go down to 450 cm-1.
Compare the spectra of the same compound from a recent publication of mine. I've analyzed the same compound using both methods so as to illustrate the difference. You can see that some of the smaller peaks that are clearly distinguishable in the KBr spectrum get lost in the noise in the ATR spectrum.
Picture
Spectrum taken using KBr disc method
Picture
Spectrum taken using ATR method
Note that both spectra were obtained with the same instrument and the same editing software.
So which should you use? If the compound is easy to make and its structure has already been proven with NMR and mass spec, then the IR is mostly a formality and you don't need the high resolution version. It might take you 20-30 min to prepare a KBr disc, while the ATR method will only take 5 min. The ATR derived spectrum still provides an unambiguous indicator of the unmistakable  functional groups such as carbonyl, hydroxyl and nitrile. However, if the compound is hard to make, you ought to characterize it in high resolution so that, especially the fingerprint region, can be matched at a later date (potentially in a natural product synthesis).
My advice is to use the ATR method when you need to characterize a library of compounds. If you're only analyzing a small handful of compounds (less than 10) then stick to the traditional KBr disc method.
0 Comments

Your comment will be posted after it is approved.


Leave a Reply.

    Matthew's Chemistry blog.

    A chronicle of tips, tricks & stories

    Contributions from readers are welcome and should be emailed to matthew.leonard742@gmail.com

    Archives

    September 2016
    December 2015
    September 2015
    July 2015
    June 2015
    May 2015
    April 2015
    March 2015
    February 2015
    January 2015
    December 2014
    November 2014
    October 2014
    September 2014
    August 2014
    July 2014
    May 2014
    March 2014
    February 2014
    January 2014
    December 2013
    November 2013
    October 2013

Powered by Create your own unique website with customizable templates.